Defect: CERTAIN MOTOR HOMES BUILT ON WORKHORSE CHASSIS AND EQUIPPED WITH ACTIA CORPORATE INSTRUMENT CLUSTERS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NOS. 101 "CONTROLS AND DISPLAYS" AND 105 "HYDRAULIC AND ELECTRIC BRAKE SYSTEMS." IF THE BRAKE FAIL INPUT FALLS BELOW A VOLTAGE OF 1.5V, THE BRAKE FAILURE LAMP AND ALARM WILL BE ACTIVATED. ALSO ACTIVATION OF THE ABS TELL (excerpt)
Consequence: AT NIGHT THE INSTRUMENT CLUSTER LIGHTS MAY FAIL AND THE DRIVER MAY NOT BE ABLE TO SEE THE INSTRUMENT PANEL GAUGES AND THE BRAKE WARNING LIGHT INDICATOR WHICH COULD INCREASING THE RISK OF A CRASH. (excerpt)
Remedy: WORKHORSE IS CONDUCTING THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN AND REPROGRAM THE INSTRUMENT PANEL CLUSTER FREE OF CHARGE. OWNERS MAY CONTACT WORKHORSE AT 1-877-246-7731 OR FOUR WINDS AT 574-266-1111. (excerpt)
Defect: CERTAIN MOTORHOMES WERE MANUFACTURED WITH A 20/15 AMP CIRCUIT BREAKER AND SHOULD HAVE BEEN MANUFACTURED WITH A 15/15 AMP CIRCUIT BREAKER.
Consequence: THIS COULD CAUSE THE BREAKER TO TRIP WHEN THE CIRCUIT IS OVERLOADED RESULTING IN A FIRE, WHICH COULD CAUSE PERSONAL INJURY OR DEATH TO THE OCCUPANTS.
Remedy: DEALERS WILL REPLACE THE INCORRECT BREAKER WITH THE CORRECT BREAKER. THE RECALL BEGAN APRIL 29, 2004. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FOUR WINDS AT 1-574-266-1111.
Defect: ON CERTAIN TRAVEL TRAILERS EQUIPPED WITH SAMSUNG MICROWAVE OVENS, THESE OVENS WERE PRODUCED WITH A DEFECTIVE PANEL. AN ELECTRICAL SHORT CAN OCCUR BETWEEN CIRCUIT PATTERNS ON THE MEMBRANE PANEL, ESPECIALLY OVERLAPPED BY A "JUMPER" OR JUMP WIRE. THIS MAY CAUSE THE OVEN TO ACTIVATE WITHOUT PRESSING ANY KEY PADS. (excerpt)
Consequence: AN ELECTRICAL SHORT CAN OCCUR CAUSING THE OVEN TO ACTIVATE WITHOUT PRESSING ANY KEY PADS. THIS COULD RESULT IN EXCESSIVE HEAT, SMOKE, OR POSSIBLY A FIRE. (excerpt)
Remedy: SAMSUNG WILL NOTIFY CUSTOMERS AND REPAIR THE PANEL FREE OF CHARGE. IN THE MEANTIME, CONSUMERS SHOULD UNPLUG THEIR MICROWAVE, IF POSSIBLE. IF THE CONSUMER IS UNABLE TO UNPLUG THE MICROWAVE, THEY SHOULD LEAVE THE DOOR AJAR UNTIL THE PANEL IS REPLACED. CONSUMERS SHOULD NEVER USE THE MICROWAVE OVEN FOR STORAGE OR LEAVE ANY TOWELS, PAPER, CLOTH OR OTHER PRODUCTS IN THE MICROWAVE AFTER USE. OWNERS W (excerpt)
Date: 2003-03-05. Systems: SERVICE BRAKES, HYDRAULIC.
Defect: CERTAIN MOTOR HOME CHASSIS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 105, "HYDRAULIC AND ELECTRIC BRAKE SYSTEMS." THE BRAKE SYSTEM WARNING INDICATOR MAY NOT FUNCTION AS REQUIRED BY STANDARD.
Consequence: IN SOME OF THE AFFECTED VEHICLES, THE BRAKE SYSTEM WARNING INDICATOR WILL NOT ILLUMINATE WHEN THE IGNITION IS IN THE START POSITION OR FOR A LOW BRAKE FLUID CONDITION, IF THE BODY BUILDER RELIED SOLELY UPON FORD'S IVM COMPLIANCE STATEMENT FOR THE BRAKE SYSTEM WARNING INDICATOR.
Remedy: DEALERS WILL REPAIR THE BRAKE WARNING LAMP CIRCUIT. OWNER NOTIFICATION BEGAN MAY 13, 2003. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FOUR WINDS AT 1-219-266-1111.
Do not drive: No. Park outside: No.
Investigations
1 investigations; 0 open.
PE04025
Opened: 2004-03-15. Closed: 2004-04-27.
INCORRECT ELECTRICAL CIRCUIT BREAKER
IN LATE FEBRUARY 2004,FOUR WINDS INTERNATIONAL NOTIFIED OWNERS OF CERTAIN MOTORHOMES BY LETTER THAT THERE WAS A NEED TO REPLACE THE FACTORY INSTALLED CIRCUIT BREAKER DUE TO AN OVERRATED CIRCUIT BREAKER BEING INSTALLED AT THE FACTORY.THIS ISSUE REPORTEDLY AFFECTS THE 110 VOLT (HOUSE CURRENT) SYSTEM OF THE COACH AND WOULD SUBJECT THE WIRES TO EXCESSIVE AMPERAGE AND OVERHEATING AND POSSIBLY CAUSE A T
Complaints from the API and bulk file are merged and deduplicated by ODI number; the API alone misses records.
System and subsystem counts are numbers of distinct complaints, recalls or communications that name them. One record can name several systems, so shares across systems can add to more than 100 percent; a single share never exceeds 100 percent.
Recalls are counted once per campaign, investigations once per action and manufacturer communications once per NHTSA id, even when NHTSA lists several model names for the same record.
A sales denominator is a calendar-year proxy, not the population of vehicles still in use. Rates are copied from verified pipeline output.
Other names NHTSA uses
None listed.
Matched NHTSA models
Matched labels and complaints
NHTSA model label
Complaints
HURRICANE
1
Check this exact car's history before you buy
Enter the car's VIN to open its history report in a new tab.