No complaints are listed for the 2016 Pierce Pumper. NHTSA's API and bulk file list none in this build.
Data build 2026-10-07.
NHTSA lists this vehicle as PIERCE PUMPER.
Model-generated complaint tags: No complaints are listed for tagging.
Recalls
1 recalls.
Date: 2016-07-21. Systems: EXTERIOR LIGHTING.
Defect: Pierce Manufacturing (Pierce) is recalling certain model year 2015-2016 Pumper and Tanker trucks built on Freightliner chassis manufactured September 27, 2014, to June 14, 2016. The affected vehicles were modified to be equipped with extended bumpers, requiring the vehicles to have additional side markers lights due to the new vehicle length. Since the vehicles do not have the necessary amount o (excerpt)
Consequence: If the vehicle is missing side marker lights, it may have reduced visibility to other drivers, increasing the risk of a crash. (excerpt)
Remedy: Pierce notified owners, and dealers will install the required side marker lamps, free of charge. The recall began on August 15, 2016. Owners may contact Pierce customer service at 1-888-974-3723. Pierce's number for this recall is 74B275. (excerpt)
Do not drive: No. Park outside: No.
Manufacturer communications
25 manufacturer communications.
Communications by system| System | Count |
|---|
| UNKNOWN OR OTHER | 20 |
|---|
| ELECTRICAL SYSTEM | 2 |
|---|
| ENGINE AND ENGINE COOLING | 1 |
|---|
| EXTERIOR LIGHTING | 1 |
|---|
| SUSPENSION | 1 |
|---|
11037322
Date: 2026-08-18. Type: Warranty Program/Extension. Systems: UNKNOWN OR OTHER.
All Roto Rays, Division of Eastern Fire Equipment Services, are warranted to the purchaser for 3 years against defects in material or workmanship. During the warranty period products found to be defective will be repaired or replaced (at Eastern Fire Equipment Services option) without charge.
11036069
Date: 2026-06-30. Type: Service Bulletin/Repair Instructions. Systems: UNKNOWN OR OTHER.
Husky XP pressure transducer troubleshooting procedure for transducer-related performance concerns.
11034151
Date: 2026-06-23. Type: Service Bulletin/Repair Instructions. Systems: UNKNOWN OR OTHER.
This bulletin will provide a quick overview of some best practices to support and extend the performance and life cycle of your PUC/NGP pump to ensure maximum operational capability.
11034150
Date: 2026-06-02. Type: Other. Systems: SUSPENSION.
The TAK-4 design was updated and older styles of TAK-4 can be upgraded. These updates to the torsion bar and torsion bar mounting are recommended but not required.
11034152
Date: 2026-06-02. Type: Service Bulletin/Repair Instructions. Systems: UNKNOWN OR OTHER.
To notify dealers and customers that the engine oil specification listed on certain Federal (FED) Tags for units equipped with PACCAR MX-13 engines may be incorrect, and to ensure proper maintenance practices are followed.
11033184
Date: 2026-05-19. Type: Service Bulletin/Repair Instructions. Systems: UNKNOWN OR OTHER.
This bulletin provides dealer guidance for MCC filter assemblies when the moisture indicator sight glass appears to show a a weta condition before installation, after installation, or on replacement filter assemblies.
11033182
Date: 2026-05-12. Type: Other. Systems: UNKNOWN OR OTHER.
Pierce has created a new style bracket that is more tolerant of stress and vibrations created from driving. This new design will allow for a longer in-service life over the old and reduce maintenance of the condenser and condenser components.
11033183
Date: 2026-05-05. Type: Service Bulletin/Repair Instructions. Systems: UNKNOWN OR OTHER.
This bulletin covers the proper procedure for the replacement/installation of grip tape on hose bed grating.
11028651
Date: 2026-01-21. Type: Service Bulletin/Repair Instructions. Systems: UNKNOWN OR OTHER.
TCU Module software patch was created to prevent and resolve the following failure modes: a ? Prognostics Not Resetting or not Staying Reset after a battery cycle. a ? Cannot Access PierceCZ.com (HTTP ERROR 500) The procedure below outlines what part/s are needed to resolve the issue.
11022609
Date: 2025-08-05. Type: Service Bulletin/Repair Instructions. Systems: UNKNOWN OR OTHER.
To improve the fitment and operational reliability of manual window cranks by installing a fabricated collar over the regulator splines, eliminating looseness and reducing effort when raising or lowering the window.